GC Column Configurator

Find and compare GC Columns with the GC Column Configurator

Use our GC Column Configurator to find the right Gas Chromatography column among more than 15,000 capillary GC columns available from all top manufacturers such as Agilent, Restek, Macherey Nagel, SGE, Thermo Scientific, etc. By using the drop-down menu on the left, you can easily select the USP specification, column description, column diameter, length and film thickness as well as the preferred manufacturer. 

Altmann Analytik GC Columns of our own brand are a high quality and cost-effective alternative. With a range of more than 5,000 GC Columns, these GC columns are available in numerous dimensions suitable for general-purpose and application-specific solutions.

Click here for more chomatography products and other chromatography supplies.

Sort By

Items 1-50 of 17207

per page
Product Image of GC Column AS-WAX MS, 30 m x 0.32 mm, 1.00 µm
GC Column AS-WAX MS, 30 m x 0.32 mm, 1.00 µm
Item number: AAGCMS-WAX-032-100-30
Brand: Altmann Analytik

In stock

€445.12 €556.40
Product Image of GC Column DB-5MS 30m, 0.25mm,  0.25µm
GC Column DB-5MS 30m, 0.25mm, 0.25µm
Item number: AG122-5532
Brand: Agilent Technologies

In stock

€803.00
Product Image of GC Capillary Column SUPELCOWAX® 10, LxID: 30 m x 0.32 mm, df 1.00 µm
GC Capillary Column SUPELCOWAX® 10, LxID: 30 m x 0.32 mm, df 1.00 µm
Item number: SU24211
Brand: Supelco

In stock

€900.19
Product Image of GC Column TraceGOLD TG-PAH, 0.1 µm, 0.18 mm x 40 m
GC Column TraceGOLD TG-PAH, 0.1 µm, 0.18 mm x 40 m
Item number: TF26055-3570
Brand: Thermo Fisher Scientific

In stock

€1,021.49
Product Image of GC Capillary column OPTIMA-5 ID: 0.53 mm, film thickness: 1 µm length: 30 m
GC Capillary column OPTIMA-5 ID: 0.53 mm, film thickness: 1 µm length: 30 m
Item number: MN726541.30
Brand: Macherey-Nagel

In stock

€657.00 €730.00
Product Image of GC Column AS-5 MS, 60 m x 0.53 mm, 1.50 µm
GC Column AS-5 MS, 60 m x 0.53 mm, 1.50 µm
Item number: AAGCMS-5-053-150-60
Brand: Altmann Analytik

In stock

€823.68 €1,029.60
Product Image of GC Column GC Column DB-WAX 30m, 0.53mm,  1.00µm
GC Column GC Column DB-WAX 30m, 0.53mm, 1.00µm
Item number: AG125-7032
Brand: Agilent Technologies

In stock

€759.60 €844.00
Product Image of GC Column TR-Pesticide 30m x 0.25mm x 0.25µm W/5M GUARD
GC Column TR-Pesticide 30m x 0.25mm x 0.25µm W/5M GUARD
Item number: TF26RF142F
Brand: Thermo Fisher Scientific

In stock

€897.84
Product Image of GC Column Alltech Heliflex AT-WAX+ 50m x 0.32mm, 1.00µm
GC Column Alltech Heliflex AT-WAX+ 50m x 0.32mm, 1.00µm
Item number: GRM8635526
Brand: Grace
€923.00
Product Image of GC column BP21, 0,25 µm, 25 m x 0,22 mm ID, Polyethylenglykol TPA treated
GC column BP21, 0,25 µm, 25 m x 0,22 mm ID, Polyethylenglykol TPA treated
Item number: SG054462
Brand: Trajan (SGE)

In stock

€663.90
Product Image of GC Capillary Column OPTIMA-1 ID: 0.32 mm, film thickness: 3 µm length: 30 m
GC Capillary Column OPTIMA-1 ID: 0.32 mm, film thickness: 3 µm length: 30 m
Item number: MN726805.30
Brand: Macherey-Nagel

In stock

€630.00
Product Image of GC Column AS-5, 60 m x 0.53 mm, 1.50 µm
GC Column AS-5, 60 m x 0.53 mm, 1.50 µm
Item number: AAGCS-5-053-150-60
Brand: Altmann Analytik
€759.53 €1,012.70
Product Image of GC Capillary Column SP-2560, L x I.D. 75 m x 0,18 mm, df 0,14 µm
GC Capillary Column SP-2560, L x I.D. 75 m x 0,18 mm, df 0,14 µm
Item number: SU23348-U
Brand: Supelco

In stock

€1,850.00
Product Image of GC Column HydroGOLD Column 10m x 0.53mm
GC Column HydroGOLD Column 10m x 0.53mm
Item number: TF26H50-1053
Brand: Thermo Fisher Scientific

In stock

€230.96
Product Image of GC Column DB-624 60m, 0.53mm,  3.00µm
GC Column DB-624 60m, 0.53mm, 3.00µm
Item number: AG125-1364
Brand: Agilent Technologies
€1,286.10 €1,429.00
Product Image of GC Capillary Column Elite-624ms, 30m x 0.32mm, 1.80µm
GC Capillary Column Elite-624ms, 30m x 0.32mm, 1.80µm
Item number: PEN9315069
Brand: PerkinElmer
€875.70 €973.00
Product Image of GC column BPX5, 0,15 µm, 30 m x 0,15 mm ID, 5% Phenyl Polysilphenylenesiloxan
GC column BPX5, 0,15 µm, 30 m x 0,15 mm ID, 5% Phenyl Polysilphenylenesiloxan
Item number: SG054110
Brand: Trajan (SGE)

In stock

€638.00
Product Image of GC Column VF-35ms 30 x 0.32 (0.25)
GC Column VF-35ms 30 x 0.32 (0.25)
Item number: AGCP8882
Brand: Agilent Technologies

In stock

€874.00
Product Image of GC Column GC,DB-1-25m-.32mm-.12µm(TND)
GC Column GC,DB-1-25m-.32mm-.12µm(TND)
Item number: AG123-1027
Brand: Agilent Technologies

In stock

€674.00
Product Image of GC Column DB-WAX 15m, 0.25mm,  0.25µm
GC Column DB-WAX 15m, 0.25mm, 0.25µm
Item number: AG122-7012
Brand: Agilent Technologies

In stock

€419.00
Product Image of GC Column TRB-PAG, 60 m x 0.53 mm x 0.5 µm
GC Column TRB-PAG, 60 m x 0.53 mm x 0.5 µm
Item number: TK550565
Brand: Teknokroma Analitica SA
€1,116.48
Product Image of GC Column AS-5 MS, 30 m x 0.53 mm, 0.50 µm
GC Column AS-5 MS, 30 m x 0.53 mm, 0.50 µm
Item number: AAGCMS-5-053-050-30
Brand: Altmann Analytik

In stock

€535.60 €669.50
Product Image of GC Column AS-1 MS FAST, 10 m x 0.10 mm, 0.20 µm
GC Column AS-1 MS FAST, 10 m x 0.10 mm, 0.20 µm
Item number: AAGCMSF-1-010-020-10
Brand: Altmann Analytik

In stock

€421.20 €526.50
Product Image of GC Column UNCORET, 12 + 3 m x 0.53 mm, 0.45 µm
GC Column UNCORET, 12 + 3 m x 0.53 mm, 0.45 µm
Item number: AAGCUNC-053-045-12-3
Brand: Altmann Analytik
€664.00 €830.00
Product Image of GC Column AS-WAX Plus, 30 + 5 m x 0.53 mm, 1 µm, with integrated AS-GAP deactivated retention Gap, 5 m
GC Column AS-WAX Plus, 30 + 5 m x 0.53 mm, 1 µm, with integrated AS-GAP deactivated retention Gap, 5 m
Item number: AAGCGAP-WAXP-053-100-30-5
Brand: Altmann Analytik
€624.00 €780.00
Product Image of GC Column AS-WAX Plus, 60 + 5 m x 0.25 mm, 0.25 µm, with integrated AS-GAP deactivated retention Gap, 5 m
GC Column AS-WAX Plus, 60 + 5 m x 0.25 mm, 0.25 µm, with integrated AS-GAP deactivated retention Gap, 5 m
Item number: AAGCGAP-WAXP-025-025-60-5
Brand: Altmann Analytik
€843.44 €1,054.30
Product Image of GC Column AS-WAX Plus, 30 + 5 m x 0.25 mm, 0.25 µm, with integrated AS-GAP deactivated retention Gap, 5 m
GC Column AS-WAX Plus, 30 + 5 m x 0.25 mm, 0.25 µm, with integrated AS-GAP deactivated retention Gap, 5 m
Item number: AAGCGAP-WAXP-025-025-30-5
Brand: Altmann Analytik
€516.88 €646.10
Product Image of GC Column AS-WAX Plus, 15 + 5 m x 0.25 mm, 0.25 µm, with integrated AS-GAP deactivated retention Gap, 5 m
GC Column AS-WAX Plus, 15 + 5 m x 0.25 mm, 0.25 µm, with integrated AS-GAP deactivated retention Gap, 5 m
Item number: AAGCGAP-WAXP-025-025-15-5
Brand: Altmann Analytik
€402.48 €503.10
Product Image of GC Column AS-624 MS, 60 + 5 m x 0.32 mm, 1.8 µm, with integrated AS-GAP deactivated retention Gap, 5 m
GC Column AS-624 MS, 60 + 5 m x 0.32 mm, 1.8 µm, with integrated AS-GAP deactivated retention Gap, 5 m
Item number: AAGCGAP-624MS-032-180-60-5
Brand: Altmann Analytik
€812.00 €1,015.00
Product Image of GC Column AS-WAX Plus FAST, 5 m x 0.15 mm, 0.15 µm
GC Column AS-WAX Plus FAST, 5 m x 0.15 mm, 0.15 µm
Item number: AAGCF-WAXP-015-015-5
Brand: Altmann Analytik
€352.56 €440.70
Product Image of GC Column AS-WAX Plus FAST, 30 m x 0.15 mm, 0.15 µm
GC Column AS-WAX Plus FAST, 30 m x 0.15 mm, 0.15 µm
Item number: AAGCF-WAXP-015-015-30
Brand: Altmann Analytik
€568.88 €711.10
Product Image of GC Column AS-WAX Plus FAST, 20 m x 0.15 mm, 0.15 µm
GC Column AS-WAX Plus FAST, 20 m x 0.15 mm, 0.15 µm
Item number: AAGCF-WAXP-015-015-20
Brand: Altmann Analytik
€559.52 €699.40
Product Image of GC Column AS-WAX Plus FAST, 15 m x 0.15 mm, 0.15 µm
GC Column AS-WAX Plus FAST, 15 m x 0.15 mm, 0.15 µm
Item number: AAGCF-WAXP-015-015-15
Brand: Altmann Analytik
€468.00 €585.00
Product Image of GC Column AS-WAX Plus FAST, 10 m x 0.15 mm, 0.15 µm
GC Column AS-WAX Plus FAST, 10 m x 0.15 mm, 0.15 µm
Item number: AAGCF-WAXP-015-015-10
Brand: Altmann Analytik
€420.16 €525.20
Product Image of GC Column AS-WAX Plus FAST, 5 m x 0.10 mm, 0.4 µm
GC Column AS-WAX Plus FAST, 5 m x 0.10 mm, 0.4 µm
Item number: AAGCF-WAXP-010-040-5
Brand: Altmann Analytik
€411.84 €514.80
Product Image of GC Column AS-WAX Plus FAST, 15 m x 0.10 mm, 0.4 µm
GC Column AS-WAX Plus FAST, 15 m x 0.10 mm, 0.4 µm
Item number: AAGCF-WAXP-010-040-15
Brand: Altmann Analytik
€538.72 €673.40
Product Image of GC Column AS-WAX Plus FAST, 10 m x 0.10 mm, 0.4 µm
GC Column AS-WAX Plus FAST, 10 m x 0.10 mm, 0.4 µm
Item number: AAGCF-WAXP-010-040-10
Brand: Altmann Analytik
€465.92 €582.40
Product Image of GC Column AS-WAX Plus FAST, 5 m x 0.10 mm, 0.2 µm
GC Column AS-WAX Plus FAST, 5 m x 0.10 mm, 0.2 µm
Item number: AAGCF-WAXP-010-020-5
Brand: Altmann Analytik
€383.76 €479.70
Product Image of GC Column AS-WAX Plus FAST, 15 m x 0.10 mm, 0.2 µm
GC Column AS-WAX Plus FAST, 15 m x 0.10 mm, 0.2 µm
Item number: AAGCF-WAXP-010-020-15
Brand: Altmann Analytik
€509.60 €637.00
Product Image of GC Column AS-WAX Plus FAST, 10 m x 0.10 mm, 0.2 µm
GC Column AS-WAX Plus FAST, 10 m x 0.10 mm, 0.2 µm
Item number: AAGCF-WAXP-010-020-10
Brand: Altmann Analytik
€437.84 €547.30
Product Image of GC Column AS-WAX Plus FAST, 5 m x 0.10 mm, 0.1 µm
GC Column AS-WAX Plus FAST, 5 m x 0.10 mm, 0.1 µm
Item number: AAGCF-WAXP-010-010-5
Brand: Altmann Analytik
€383.76 €479.70
Product Image of GC Column AS-WAX Plus FAST, 15 m x 0.10 mm, 0.1 µm
GC Column AS-WAX Plus FAST, 15 m x 0.10 mm, 0.1 µm
Item number: AAGCF-WAXP-010-010-15
Brand: Altmann Analytik
€509.60 €637.00
Product Image of GC Column AS-WAX Plus FAST, 10 m x 0.10 mm, 0.1 µm
GC Column AS-WAX Plus FAST, 10 m x 0.10 mm, 0.1 µm
Item number: AAGCF-WAXP-010-010-10
Brand: Altmann Analytik
€437.84 €547.30
Product Image of GC Column AS-WAX Plus FAST, 5 m x 0.05 mm, 0.05 µm
GC Column AS-WAX Plus FAST, 5 m x 0.05 mm, 0.05 µm
Item number: AAGCF-WAXP-005-005-5
Brand: Altmann Analytik
€461.76 €577.20
Product Image of GC Column AS-WAX Plus FAST, 2.5 m x 0.05 mm, 0.05 µm
GC Column AS-WAX Plus FAST, 2.5 m x 0.05 mm, 0.05 µm
Item number: AAGCF-WAXP-005-005-2-5
Brand: Altmann Analytik
€333.84 €417.30
Product Image of GC Column AS-WAX Plus FAST, 2 m x 0.05 mm, 0.05 µm
GC Column AS-WAX Plus FAST, 2 m x 0.05 mm, 0.05 µm
Item number: AAGCF-WAXP-005-005-2
Brand: Altmann Analytik
€317.20 €396.50
Product Image of GC Column AS-WAX Plus, 75 m x 0.53 mm, 2.5 µm
GC Column AS-WAX Plus, 75 m x 0.53 mm, 2.5 µm
Item number: AAGCC-WAXP-053-250-75
Brand: Altmann Analytik
€1,010.88 €1,263.60
Product Image of GC Column AS-WAX Plus, 60 m x 0.53 mm, 2.5 µm
GC Column AS-WAX Plus, 60 m x 0.53 mm, 2.5 µm
Item number: AAGCC-WAXP-053-250-60
Brand: Altmann Analytik
€847.60 €1,059.50
Product Image of GC Column AS-WAX Plus, 50 m x 0.53 mm, 2.5 µm
GC Column AS-WAX Plus, 50 m x 0.53 mm, 2.5 µm
Item number: AAGCC-WAXP-053-250-50
Brand: Altmann Analytik
€775.84 €969.80
Product Image of GC Column AS-WAX Plus, 30 m x 0.53 mm, 2.5 µm
GC Column AS-WAX Plus, 30 m x 0.53 mm, 2.5 µm
Item number: AAGCC-WAXP-053-250-30
Brand: Altmann Analytik
€576.16 €720.20

Find the right GC Column

When selecting a GC column for your analysis, it can be difficult to choose the most appropriate column since there is a wide range of options. However, considering a number of questions about the planned separation makes the choice a lot easier. Read the following information to find the most suitable column for your analysis.

Method development considerations

When first developing a method, you should consider these column characteristics to determine the best column for the separation:

1) Column phase
2) Internal diameter
3) Film thickness
4) Column length

1) Column phase

The polarity oft he stationary phase is chosen according to the compounds to analyze. In GC, the separation of two analytes occurs due to differences in their interaction with the stationary phase, therefore a phase must be chosen that matches the properties of the sample.

Non polar phases separate compounds by their boiling points. For example, if the components have different boiling points (greater than 2°C), a non-polar column such as the TG-1MS or DB-1 / DB-5 is recommended.

Intermediate polarity phases such as DB-WAX or DB-1701, combine boiling point with the more selective hydrogen bridge or dipolar moment interactions and thus provide a higher selectivity.

If the products differ primarily in their polarities, then a polar column such as the TG-WaxMS will be ideal.

In general, non polar phases are more thermally stable than the polar phases. In other words, the higher the column polarity, the lower ist thermal stability. Hence, always select the least polar column which will perform the separation.

2) Internal diameter

The choice of inner diameter is often determined by the instrument or detection method. Most modern GC instruments are suitable for most column sizes. The internal diameter (ID) of a column is inversely proportional to ist separation power. With a larger inner diameter, the sample capacity of the column increases, but resolution and sensitivity decrease. Vice versa, a column with a smaller inner diameter can improve resolution and sensitivity, but with the drawback of lower sample capacity and higher sample preparation requirements. It is therefore a good idea to find a similar application that allows separation of the desired components and use this as a guide.

For samples containing a large number of substances where you may need a high resolution, small internal diameter columns (0.20-0.25 mm) are recommended. For samples with a high range of concentrations wider columns should be used since these larger diameters allow fort he injection of a higher sample amount.
Columns of 0.53 mm ID (semicapillary) have a loading capacity similar to that of packed columns, but with better resolution, improved chemical inertness and lower analysis times.

The 0.32-0.53 mm ID columns can be used with either a standard injector (that is used for capillary columns) or with a packed column injector, as they can operate at high flow rates. For GC-MS systems it is recommended to work with small ID columns (0.10 mm, 0.15 mm, 0.18 mm, 0.20 mm, and 0.22 mm) so as not to exceed the capacity oft he MS vacuum system.

Capillary columns of 0.1 mm ID can generate high plates numbers and reduce analysis time without losing resolution. The high efficiency of these columns (7000-10,000 plates/meter) allows the resolution of complex samples using shorter column lengths. However their loading capacity is a limiting factorr and in order to obtain the best performance from these columns instrumental factors (injector/detector) have to be taken into account.

3) Film thickness

The film thickness of the column has an influence on retention, dissolution, column bleed, inertness and capacity. Increasing the film thickness increases the sample capacity of the column and slows down the elution of the peaks, which can be helpful when analyzing volatile compounds. A thicker film also reduces the risk of overloading the column, thus improving the resolution. However, a thicker film may also be more sensitive to degradation. The same component will elute at a higher temperature on a thick film than on a thin film.

Compounds with high boiling points or high molecular weight should be analyzed with a thin film to improve resolution and avoid unnecessarily long analysis times. As a general rule, thin films (0.1 µm) must be used for compounds with a high molecular weight such as rilycerides, antioxitants etc., which have elution temperatures over 300 °C. 

Another essential factor is the phase ratio, which can be calculated based on the inner diameter and the film thickness. The phase ratio is considered 1) to characterize the best dimensions for an application and 2) when an analysis is to be transferred from one column with a certain inner diameter to another without changing the method significantly.

A film thickness of 0.25-0.32 µm ist he standard thickness allowing for a compromise between capacity and resolution; and fort he injection of samples with a wide volatility range.

Thick films increase retention of the most volatile components whereas thin films provide faster elution at lower temperatures. Thick films must be used for low boiling substances. Specifically, 3-5 µm films are used to separate solvents, gases, and very volatile substances at room temperature or lower. When the thickness oft he stationary phase increases, thermal stability decreases. Therefore the bleed level is higher and this can limit the maximum operating temperature oft he column.

4) Column length

A longer column length leads to higher efficiency and resolution, but it is not a linear relationship. The resolution is proportional to the square root of the column length, so doubling the column length increases the resolution by about 40%. However, increasing the column length also increases the retention time. Double column length, double analysis time. In general, it is recommended to use the shortest column with which the desired separation can be performed.

  • Columns with a length of 25 to 30 meters are suitable for the beginning of method development. This provides a high efficiency with relatively shot analysis times. 
  • Columns 10 to 15 meters long are suitable for samples containing very few or easily separable analytes. Shorter columns are used for very small diameters to reduce initial pressure.
  • Columns 50 to 60 meters long should only be used when resolution is not possible by other means (smaller diameter, different stationary phase, temperature change of the column). However, they are ideal for complex samples with many substances. Long columns require a long analysis time and cause higher costs.

Some additional considerations

It is useful to know that 95% of all used GC columns are either TG-1MS, TG-5MS, or TG-WaxMS type columns. A good starting column is a 30m x 0.25mm ID, 5% phenyl column with a film thickness of 0.25μm, such as e.g. the TG-5MS. This is a non-polar column that separates primarily by boiling point, but also has some polar characteristics.