Liner

THe Analytics Shop offers a good selection of liners by SGE, Agilent Technologies and Vici Valco. The GC inlet liner is where the sample is introduced and vaporized into the gaseous phase. The design of the liner is crucial. Selecting the right inlet liner and injection parameter can increase peak areas and reduce detection limits by up to 300 %. Liner deactivation is also important to ensure reproducible and accurate chromatography results.

If you have any questions on GC liners and other GC supplies, please contact our independent team of experts for professional advice.

Sort By

Items 51-100 of 905

per page
Product Image of Liner, Ultra Inert, split/splitless, gooseneck, 2 mm, Varian/Bruiker, 5 pc/PAK
Liner, Ultra Inert, split/splitless, gooseneck, 2 mm, Varian/Bruiker, 5 pc/PAK
Item number: AG8004-0178
Brand: Agilent Technologies
$262.65
Product Image of Liner, Ultra Inert, splitlesss, straight, wool, 4 mm, Varian/Bruiker, 5 pc/PAK
Liner, Ultra Inert, splitlesss, straight, wool, 4 mm, Varian/Bruiker, 5 pc/PAK
Item number: AG8004-0173
Brand: Agilent Technologies
$168.54
Product Image of Liner, Ultra Inert, split/splitless, gooseneck, wool, 4 mm, Varian/Bruiker, 5 pc/PAK
Liner, Ultra Inert, split/splitless, gooseneck, wool, 4 mm, Varian/Bruiker, 5 pc/PAK
Item number: AG8004-0170
Brand: Agilent Technologies
$238.58
Product Image of Liner, Ultra Inert, direct, double taper, 0.53 mm id column, 45 mm, Varian/Bruiker, 5 pc/PAK
Liner, Ultra Inert, direct, double taper, 0.53 mm id column, 45 mm, Varian/Bruiker, 5 pc/PAK
Item number: AG8004-0168
Brand: Agilent Technologies
$362.24
Product Image of Liner, Ultra Inert, direct, single point inlet (SPI) 0.25/0.32 mm Columns, 0.5 mm, Varian/Bruiker, 5 pc/PAK
Liner, Ultra Inert, direct, single point inlet (SPI) 0.25/0.32 mm Columns, 0.5 mm, Varian/Bruiker, 5 pc/PAK
Item number: AG8004-0167
Brand: Agilent Technologies
$291.10
Product Image of Liner, Ultra Inert, splitless, gooseneck, 4 mm, Varian/Bruiker, 5 pc/PAK
Liner, Ultra Inert, splitless, gooseneck, 4 mm, Varian/Bruiker, 5 pc/PAK
Item number: AG8004-0165
Brand: Agilent Technologies
$194.80
Product Image of Liner, Ultra Inert, split, gooseneck, 3.4 mm, Varian/Bruiker, 5 pc/PAK
Liner, Ultra Inert, split, gooseneck, 3.4 mm, Varian/Bruiker, 5 pc/PAK
Item number: AG8004-0164
Brand: Agilent Technologies
$299.86
Product Image of Liner, Ultra Inert, split, wool, 4 mm, Varian/Bruiker, 5 pc/PAK
Liner, Ultra Inert, split, wool, 4 mm, Varian/Bruiker, 5 pc/PAK
Item number: AG8004-0163
Brand: Agilent Technologies
$292.20
Product Image of Liner, Ultra Inert, 0.5 mm restriction, SPI 0.53 mm ID On-Column, 0.8mm, Varian/Bruiker, 5 pc/PAK
Liner, Ultra Inert, 0.5 mm restriction, SPI 0.53 mm ID On-Column, 0.8mm, Varian/Bruiker, 5 pc/PAK
Item number: AG8004-0162
Brand: Agilent Technologies
$283.44
Product Image of Liner, Ultra Inert, splitless, single taper, 2 mm, Varian/Bruiker, 5 pc/PAK
Liner, Ultra Inert, splitless, single taper, 2 mm, Varian/Bruiker, 5 pc/PAK
Item number: AG8004-0161
Brand: Agilent Technologies
$234.20
Product Image of Liner, Ultra Inert, frit gooseneck 3.4 mm, Varian/Bruiker, 5 pc/PAK
Liner, Ultra Inert, frit gooseneck 3.4 mm, Varian/Bruiker, 5 pc/PAK
Item number: AG8004-0159
Brand: Agilent Technologies
$350.20
Product Image of Liner, Ultra Inert, split, frit goosneck 4 mm, Varian/Bruiker, 5 pc/PAK
Liner, Ultra Inert, split, frit goosneck 4 mm, Varian/Bruiker, 5 pc/PAK
Item number: AG8004-0158
Brand: Agilent Technologies
$357.86
Product Image of Liner, Ultra Inert, direct straight, 1.2 mm, Varian/Bruiker, 5 pc/PAK
Liner, Ultra Inert, direct straight, 1.2 mm, Varian/Bruiker, 5 pc/PAK
Item number: AG8004-0157
Brand: Agilent Technologies
$147.74
Product Image of Liner, Ultra Inert, split, straight, 4 mm, Varian/Bruiker, 5 pc/PAK
Liner, Ultra Inert, split, straight, 4 mm, Varian/Bruiker, 5 pc/PAK
Item number: AG8004-0156
Brand: Agilent Technologies
$116.00
Product Image of Liner, Ultra Inert, splitless, dual taper, 4 mm, Varian/Bruiker, 5 pc/PAK
Liner, Ultra Inert, splitless, dual taper, 4 mm, Varian/Bruiker, 5 pc/PAK
Item number: AG8004-0155
Brand: Agilent Technologies
$201.36
Product Image of Liner, Ultra Inert, split, straight, wool, 4 mm, Varian/Bruiker, 5 pc/PAK
Liner, Ultra Inert, split, straight, wool, 4 mm, Varian/Bruiker, 5 pc/PAK
Item number: AG8004-0154
Brand: Agilent Technologies
$136.80
Product Image of Liner,UI recessd taper wool 4 mm 5 pk V-B, recessed gooseneck, wool
Liner,UI recessd taper wool 4 mm 5 pk V-B, recessed gooseneck, wool
Item number: AG8004-0153
Brand: Agilent Technologies
$179.48
Product Image of Liner, Ultra Inert, splitless, single taper, wool, 4 mm, 5 pc/PAK V-B
Liner, Ultra Inert, splitless, single taper, wool, 4 mm, 5 pc/PAK V-B
Item number: AG8004-0152
Brand: Agilent Technologies
$175.10
Product Image of Liner, Ultra Inert, splitless, single taper, 4 mm, Varian/Bruiker, 5 pc/PAK
Liner, Ultra Inert, splitless, single taper, 4 mm, Varian/Bruiker, 5 pc/PAK
Item number: AG8004-0151
Brand: Agilent Technologies
$168.54
Product Image of Liner, Ulltra Inert, Split, bottom restrict, 4 mm, PE, 5 pc/PAK
Liner, Ulltra Inert, Split, bottom restrict, 4 mm, PE, 5 pc/PAK
Item number: AG8003-0166
Brand: Agilent Technologies
$203.55
Product Image of Liner, Ultra Inert, splitless, straight, 2 mm, PE, 5 pc/PAK
Liner, Ultra Inert, splitless, straight, 2 mm, PE, 5 pc/PAK
Item number: AG8003-0162
Brand: Agilent Technologies
$218.88
Product Image of Liner, Ultra Inert, Split, straight, wool, 4 mm, PE, 5 pc/PAK
Liner, Ultra Inert, Split, straight, wool, 4 mm, PE, 5 pc/PAK
Item number: AG8003-0160
Brand: Agilent Technologies
$416.96
Product Image of Liner, Ultra Inert, split/splitless ,bottom restrict, 4 mm, PE, 5 pc/PAK
Liner, Ultra Inert, split/splitless ,bottom restrict, 4 mm, PE, 5 pc/PAK
Item number: AG8003-0159
Brand: Agilent Technologies
$228.73
Product Image of Liner, Ultra Inert, PSS, bottom restrict, 2 mm, PE, 5 pc/PAK
Liner, Ultra Inert, PSS, bottom restrict, 2 mm, PE, 5 pc/PAK
Item number: AG8003-0158
Brand: Agilent Technologies
$306.43
Product Image of Liner, Ultra Inert, PSS, split/splitles,s straight, 1 mm, PE, 5 pc/PAK
Liner, Ultra Inert, PSS, split/splitles,s straight, 1 mm, PE, 5 pc/PAK
Item number: AG8003-0157
Brand: Agilent Technologies
$408.20
Product Image of Liner, Ultra Inert, DI, gooseneck, top hole, wool, 4 mm, PE, 5 pc/PAK
Liner, Ultra Inert, DI, gooseneck, top hole, wool, 4 mm, PE, 5 pc/PAK
Item number: AG8003-0155
Brand: Agilent Technologies
$488.09
Product Image of Liner, Ultra Inert, PSS, straight, 2 mm, PE, 5 pc/PAK
Liner, Ultra Inert, PSS, straight, 2 mm, PE, 5 pc/PAK
Item number: AG8003-0153
Brand: Agilent Technologies
$244.05
Product Image of Liner, Ultra Inert, PTV straight 1 mm, TMO, 5 pc/PAK
Liner, Ultra Inert, PTV straight 1 mm, TMO, 5 pc/PAK
Item number: AG8002-0161
Brand: Agilent Technologies
$439.94
Product Image of Liner, Ultra Inert, PTV 6 baffles 2 mm, TMO, 5 pc/PAK
Liner, Ultra Inert, PTV 6 baffles 2 mm, TMO, 5 pc/PAK
Item number: AG8002-0160
Brand: Agilent Technologies
$390.69
Product Image of Liner, Ultra Inert, PTV bottom restriction 2 mm, TMO, 5 pc/PAK
Liner, Ultra Inert, PTV bottom restriction 2 mm, TMO, 5 pc/PAK
Item number: AG8002-0157
Brand: Agilent Technologies
$283.44
Product Image of Liner, Ultra Inert, PTV straight 2 mm, TMO, 5 pc/PAK
Liner, Ultra Inert, PTV straight 2 mm, TMO, 5 pc/PAK
Item number: AG8002-0156
Brand: Agilent Technologies
$310.80
Product Image of Liner, Ultra Inert, splitlesss single taper 3 mm, TMO, 5 pc/PAK
Liner, Ultra Inert, splitlesss single taper 3 mm, TMO, 5 pc/PAK
Item number: AG8002-0154
Brand: Agilent Technologies
$267.03
Product Image of Liner, Ultra Inert, splitless single taper 5 mm, TMO, 5 pc/PAK
Liner, Ultra Inert, splitless single taper 5 mm, TMO, 5 pc/PAK
Item number: AG8002-0153
Brand: Agilent Technologies
$259.36
Product Image of Liner, Ultra Inert, splitles straight 3 mm, TMO, 5 pc/PAK
Liner, Ultra Inert, splitles straight 3 mm, TMO, 5 pc/PAK
Item number: AG8002-0152
Brand: Agilent Technologies
$194.80
Product Image of Liner, Ultra Inert, split straight 5 mm, TMO, 5 pc/PAK
Liner, Ultra Inert, split straight 5 mm, TMO, 5 pc/PAK
Item number: AG8002-0151
Brand: Agilent Technologies
$183.85
Product Image of Inlet Liner, Ultra Inert, straight, 1.25 mm, Shimadzu, for PTV, 5 pc/PAK
Inlet Liner, Ultra Inert, straight, 1.25 mm, Shimadzu, for PTV, 5 pc/PAK
Item number: AG8001-0163
Brand: Agilent Technologies
$338.16
Product Image of Inlet Liner, Ultra Inert, splitless, single taper, wool, 3.5,mm, Shimadzu, 5 pc/PAK
Inlet Liner, Ultra Inert, splitless, single taper, wool, 3.5,mm, Shimadzu, 5 pc/PAK
Item number: AG8001-0160
Brand: Agilent Technologies
$256.09
Product Image of Inlet Liner, Ultra Inert, splitless, double taper, drilled hole near bottom, 3.5 mm, Shimadzu, 5 pc/PAK
Inlet Liner, Ultra Inert, splitless, double taper, drilled hole near bottom, 3.5 mm, Shimadzu, 5 pc/PAK
Item number: AG8001-0159
Brand: Agilent Technologies
$514.36
Product Image of Inlet Liner, Ultra Inert, splitless, double taper, drilled hole near top, 3.5 mm, Shimadzu, 5 pc/PAK
Inlet Liner, Ultra Inert, splitless, double taper, drilled hole near top, 3.5 mm, Shimadzu, 5 pc/PAK
Item number: AG8001-0158
Brand: Agilent Technologies
$545.00
Product Image of Inlet Liner, Ultra Inert, split, straight with restriction restrict, wool, 3.5 mm, Shimadzu, 5 pc/PAK
Inlet Liner, Ultra Inert, split, straight with restriction restrict, wool, 3.5 mm, Shimadzu, 5 pc/PAK
Item number: AG8001-0157
Brand: Agilent Technologies
$256.09
Product Image of Inlet Liner, Ultra Inert, split, straight with middle restriction, 3.5 mm, Shimadzu, 5 pc/PAK
Inlet Liner, Ultra Inert, split, straight with middle restriction, 3.5 mm, Shimadzu, 5 pc/PAK
Item number: AG8001-0156
Brand: Agilent Technologies
$203.55
Product Image of Inlet Liner, Ultra Inert, split/splitless, single taper, 3.4 mm, Shimadzu, 5 pc/PAK
Inlet Liner, Ultra Inert, split/splitless, single taper, 3.4 mm, Shimadzu, 5 pc/PAK
Item number: AG8001-0154
Brand: Agilent Technologies
$281.25
Product Image of Inlet Liner, Ultra Inert, split, straight, 3.4 mm, Shimadzu, 5 pc/PAK
Inlet Liner, Ultra Inert, split, straight, 3.4 mm, Shimadzu, 5 pc/PAK
Item number: AG8001-0153
Brand: Agilent Technologies
$121.48
Product Image of Liner,UI straight 2.6 mm, SHM, 5 pc/PAK
Liner,UI straight 2.6 mm, SHM, 5 pc/PAK
Item number: AG8001-0151
Brand: Agilent Technologies
$101.89
Product Image of Liner, UI, Direct Connect,bottom hole,5pk
Liner, UI, Direct Connect,bottom hole,5pk
Item number: AG5190-7020
Brand: Agilent Technologies
$423.53
Product Image of Liner, UI, Direct Connect, no hole,wool,5pk
Liner, UI, Direct Connect, no hole,wool,5pk
Item number: AG5190-7014
Brand: Agilent Technologies
$426.81
Product Image of Liner, UI, Direct Conn, no hole, no wool,5pk
Liner, UI, Direct Conn, no hole, no wool,5pk
Item number: AG5190-7013
Brand: Agilent Technologies
$420.24
Product Image of Liner, UI, Direct Conn,top hole w wool,5pk
Liner, UI, Direct Conn,top hole w wool,5pk
Item number: AG5190-7012
Brand: Agilent Technologies
$426.81
Product Image of Liner, UI, Direct Connect,dual taper,5pk
Liner, UI, Direct Connect,dual taper,5pk
Item number: AG5190-7011
Brand: Agilent Technologies
$439.94
Product Image of Liner, Ultra Inert, gerade, 2 mm ID
Liner, Ultra Inert, gerade, 2 mm ID
Item number: AG5190-6168
Brand: Agilent Technologies
$42.84

Liner represent an indispensable element for a proper functioning of the GC system. They allow an injected liquid sample the transition to the volatile phase and then into the GC column. The elevated temperature in the inlet vaporizes the liquid sample for transfer to the head of the GC column. The result is a significant change in the volume during the phase transition - the volume of the resulting vapor has to remain within the volume of the liner. If the expansion volume is too large, the sample can be lost, resulting in a poor reproducibility and sensitivity and this may lead to carryover the entire GC system.

The selection of a suitable liner for your GC system is, however, often not very simple but very important. The key aspects you should consider are the following:

  • Liner ID and geometry
  • Type of injection
  • Packing materials of the liner
  • Treatment or deactivation of the liner

1. Liner ID and geometry

Different liner IDs are indicators of varying volumes. A number of factors affect or reduce the effective volume of a liner, for example:

  • taper, baffles and other liner features
  • packing materials
  • carrier gas

In general the vapor cloud formed by the sample should not exceed half of the total volume of the liner. The expansion volume of solvents limits the injection volume. Solvents with low density and high molecular weight are desirable - this increases the volume of the solvent which can decrease the injected and detection limits.

2. Type of injection

Another key aspect in the selection of a suitable liner is the type of injection. Split liner allow the split flow over the bottom of the liner and causes a removal of a portion of the sample. This allows the implementation of a split injection. A selection of split liner you can find here.

Splitless Liners are usually tapered at the bottom. This helps to convey the sample to the column and minimizes sample contact with reactive metal components in the inlet during injection.

3. Packing material of the liner

The active sites of Inlet liners can adsorb sample components and cause peak tailing. This can lead to a loss of sensitivity and reproducibility. Active sites may also cause deterioration in certain classes of compounds.

4. Deactivation / treatment of the liner

In the Analytics-Shop users can choose from a wide range of liners from numerous manufacturers. These high quality liners offer a significantly improved inertness for a wide range of compounds. With various deactivation processes they often provide enhanced transferring the sample to the GC column, resulting in increased accuracy and precision in the analysis itself. This allows lower detection limits for some agents.

In our offer you will find a wide range of high quality liners and any other accessories for the (gas) chromatography. Questions about our products? Our expert team will be happy to advise you.

When the liners are not exchanged in regular intervals, this can lead to huge problems. Firstly, a used liner cannot guarantee consistent reproducibility, which could affect the entire GC system. Furthermore, the liner should be replaced from time to time in order to avoid degradation of the peak shape and sample disintegration. So-called "ghost peaks" can also be a result of liners that haven't been exchanged in too long.

Sky Inlet Liners increase accuracy and reproducibility with state-of-the-art deactivation. These liners achieve lower detection limits for a wide range of active compounds. The innovative deactivation used for Sky liners leads to exceptional inertness for a wide range of analyte chemistries. By reducing active sites and enhancing analyte transfer to the column, these liners increase accuracy and precision, allowing lower detection limits for many active compounds. Also fewer liner changes are needed and less downtime for maintenance.