HPLC Inline-Filter

To keep HPLC and UHPLC systems free of contaminants that can damage the analytical column or even the entire system, the highest purity for all solutions that come into direct contact with the plant is necessary. In addition to regular maintenance of the system it is recommended to use an inline-filter to protect the column and the plant. The housing of the inline-filter is made of PEEK or stainless steel with a frit in the interior and standard fittings at both ends. There are inline-filters, which are completely replaced if necessary, or a variant in which only the frit must be replaced.

We carry numerous inline-filters of well-known manufacturers such as Agilent Technologies, Vici Jour and Merck. If you have any problems when choosing a product, feel free to contact us.

Sort By

Items 1-50 of 138

per page
Product Image of Precolumn Filter Insert Assembly
Precolumn Filter Insert Assembly
Item number: WTWAT088084
Brand: Waters

In stock

€28.00
Product Image of Inline Filter, ADS, 5 gaskets, PEEK Filter, for LiChroCART
Inline Filter, ADS, 5 gaskets, PEEK Filter, for LiChroCART
Item number: MC1511920001
Brand: Merck
€205.60 €257.00
Product Image of Precolumn Filter Assy 2µm, 1pc/PAK
Precolumn Filter Assy 2µm, 1pc/PAK
Item number: UPA-315
Brand: Upchurch Scientific

In stock

€100.52
Product Image of SemiPrep Inline Filter Assembly, 10µm, 1pc/PAK
SemiPrep Inline Filter Assembly, 10µm, 1pc/PAK
Item number: UPA-411
Brand: Upchurch Scientific
€172.64
Product Image of Inline Filter Assembly, 0.5µm, 1pc/PAK
Inline Filter Assembly, 0.5µm, 1pc/PAK
Item number: UPA-431
Brand: Upchurch Scientific
€57.89
Product Image of SemiPrep Filter, 5µm, for 3/16'' OD, 1pc/PAK
SemiPrep Filter, 5µm, for 3/16'' OD, 1pc/PAK
Item number: UPA-510
Brand: Upchurch Scientific
€176.06
Product Image of Precolumn MicroFilter, 0.5µm, PEEK, for 1/16'' OD, with 5 PEEK frits, 1pc/PAK
Precolumn MicroFilter, 0.5µm, PEEK, for 1/16'' OD, with 5 PEEK frits, 1pc/PAK
Item number: UPM-560
Brand: Upchurch Scientific

In stock

€181.92
Product Image of Line Filter, SS, for Shimadzu model LC-30AD
Line Filter, SS, for Shimadzu model LC-30AD
Item number: 228-35871-99ASP
Brand: Altmann Analytik
€149.35
Product Image of Line Filter Assembly, equivalent product to Shimadzu 228-35871-96
Line Filter Assembly, equivalent product to Shimadzu 228-35871-96
Item number: 228-35871-96ASP
Brand: Altmann Analytik

In stock

€66.77 €69.28
Product Image of Precolumn Filter, PEEK, 2µm, 1pc/PAK
Precolumn Filter, PEEK, 2µm, 1pc/PAK
Item number: UPA-355
Brand: Upchurch Scientific

In stock

€93.83
Product Image of Inline MicroFilter Assembly, with 5 fittings, 1pc/PAK
Inline MicroFilter Assembly, with 5 fittings, 1pc/PAK
Item number: UPM-520
Brand: Upchurch Scientific
€161.85
Product Image of Inline Filter, filter cartridge
Inline Filter, filter cartridge
Item number: MC1511930001
Brand: Merck
€165.75 €195.00
Product Image of Precolumn Filter Female End, 1pc/PAK
Precolumn Filter Female End, 1pc/PAK
Item number: UPA-315-01
Brand: Upchurch Scientific
€48.84
Product Image of Precolumn Filter, 2 µm, for 1/16'' OD + Holder, PEEK (350 bar)
Precolumn Filter, 2 µm, for 1/16'' OD + Holder, PEEK (350 bar)
Item number: YMXRPRCP02
Brand: YMC
€269.00
Product Image of Replacement Precolumn Filter 2 µm for 1/16'' o.d., PEEK (350 bar), 5 pc/PAK
Replacement Precolumn Filter 2 µm for 1/16'' o.d., PEEK (350 bar), 5 pc/PAK
Item number: YMXRPRCP25
Brand: YMC
€196.00
Product Image of 2µm Frit Column Filters, 10pc/PAK
2µm Frit Column Filters, 10pc/PAK
Item number: FT-2-SAV10
Brand: Fortis
€539.73
Product Image of In-Line precolumn Filter kit
In-Line precolumn Filter kit
Item number: WTWAT084560
Brand: Waters

In stock

€394.00
Product Image of Inline Filter, housing assembly
Inline Filter, housing assembly
Item number: QLFILASY-DK
Brand: QLA
€81.59
Product Image of Precolumn Filter, 0.5µm, 1,3µl swept volume, 1pc/PAK
Precolumn Filter, 0.5µm, 1,3µl swept volume, 1pc/PAK
Item number: UPA-316
Brand: Upchurch Scientific
€101.34
Product Image of Precolumn Filter, 0.5µm, 0, 84µl swept volume, 1pc/PAK
Precolumn Filter, 0.5µm, 0, 84µl swept volume, 1pc/PAK
Item number: UPA-318
Brand: Upchurch Scientific
€128.86
Product Image of SemiPrep Filter Assembly, 10 µm, 1pc/PAK
SemiPrep Filter Assembly, 10 µm, 1pc/PAK
Item number: UPA-330
Brand: Upchurch Scientific
€167.91
Product Image of Precolumn Filter, PEEK, 0.5µm, 1pc/PAK
Precolumn Filter, PEEK, 0.5µm, 1pc/PAK
Item number: UPA-356
Brand: Upchurch Scientific
€96.10
Product Image of SemiPrep Filter Assembly, 10µm, 1pc/PAK
SemiPrep Filter Assembly, 10µm, 1pc/PAK
Item number: UPA-360
Brand: Upchurch Scientific
€308.16
Product Image of SemiPrep Inline Filter Assembly, 2µm, 1pc/PAK
SemiPrep Inline Filter Assembly, 2µm, 1pc/PAK
Item number: UPA-410
Brand: Upchurch Scientific
€172.64
Product Image of Low Pressure Inline Filter, 2 µm, for 1/16'' OD, minimum order amount 5 pcs.
Low Pressure Inline Filter, 2 µm, for 1/16'' OD, minimum order amount 5 pcs.
Item number: UPA-415
Brand: Upchurch Scientific
€44.60
Product Image of Low Pressure Inline Filter, 2 µm, for 1/8'' OD, 1pc/PAK
Low Pressure Inline Filter, 2 µm, for 1/8'' OD, 1pc/PAK
Item number: UPA-416
Brand: Upchurch Scientific
€44.60
Product Image of Inline Filter, metal free, 2µm, for 1/16'' OD, 1pc/PAK
Inline Filter, metal free, 2µm, for 1/16'' OD, 1pc/PAK
Item number: UPA-424
Brand: Upchurch Scientific
€34.50
Product Image of Inline Filter, metal free, 10µm, for 1/16'' OD, 1pc/PAK
Inline Filter, metal free, 10µm, for 1/16'' OD, 1pc/PAK
Item number: UPA-425
Brand: Upchurch Scientific
€31.53
Product Image of Inline Filter Assembly, 2µm, 1pc/PAK
Inline Filter Assembly, 2µm, 1pc/PAK
Item number: UPA-430
Brand: Upchurch Scientific
€53.67
Product Image of Precolumn MicroFilter Assembly 0.5µm, 5 SS frits, 1pc/PAK
Precolumn MicroFilter Assembly 0.5µm, 5 SS frits, 1pc/PAK
Item number: UPM-500
Brand: Upchurch Scientific
€195.43
Product Image of Precolumn MicroFilter Assembly, 1pc/PAK
Precolumn MicroFilter Assembly, 1pc/PAK
Item number: UPM-510
Brand: Upchurch Scientific
€181.92
Product Image of Mini MicroFilter Assembly, 1µm, for 1/32'' OD, with SS frit disc, 1pc/PAK
Mini MicroFilter Assembly, 1µm, for 1/32'' OD, with SS frit disc, 1pc/PAK
Item number: UPM-547
Brand: Upchurch Scientific
€421.92
Product Image of Precolumn MicroFilter, 0.5µm, with 5 SSfrits, 1pc/PAK
Precolumn MicroFilter, 0.5µm, with 5 SSfrits, 1pc/PAK
Item number: UPM-550
Brand: Upchurch Scientific
€195.43
Product Image of Precolumn MicroFilter, 2µm, for 1/16'' OD, with 1 SSfrit, 1pc/PAK
Precolumn MicroFilter, 2µm, for 1/16'' OD, with 1 SSfrit, 1pc/PAK
Item number: UPM-555-1
Brand: Upchurch Scientific
€150.68
Product Image of Precolumn MicroFilter, 0.5µm, PEEK, for 1/16'' OD, with 1 PEEK frit, 1pc/PAK
Precolumn MicroFilter, 0.5µm, PEEK, for 1/16'' OD, with 1 PEEK frit, 1pc/PAK
Item number: UPM-560-1
Brand: Upchurch Scientific
€392.64
Product Image of Sure-Guard, disposable In-Line Filter,SS frit 0.5 um, minimum order amount = 4 pcs
Sure-Guard, disposable In-Line Filter,SS frit 0.5 um, minimum order amount = 4 pcs
Item number: JR-0611-SS05
Brand: Vici Jour
€26.88
Product Image of Sure-Guard, disposable In-Line Filter,SS frit 2.0 um, minimum order amount = 4 pcs
Sure-Guard, disposable In-Line Filter,SS frit 2.0 um, minimum order amount = 4 pcs
Item number: JR-0611-SS2
Brand: Vici Jour
€26.88
Product Image of Sure-Guard, disposable In-Line Filter, TI frit 0.5 um, minimum order amount = 4 pcs
Sure-Guard, disposable In-Line Filter, TI frit 0.5 um, minimum order amount = 4 pcs
Item number: JR-0611-TI05
Brand: Vici Jour
€26.88
Product Image of Sure-Guard, disposable In-Line Filter, TI frit 2.0 um, minimum order amount = 4 pcs
Sure-Guard, disposable In-Line Filter, TI frit 2.0 um, minimum order amount = 4 pcs
Item number: JR-0611-TI2
Brand: Vici Jour
€26.88
Product Image of Filter (Last Drop) with, 2µm SS Filter
Filter (Last Drop) with, 2µm SS Filter
Item number: WTPSL901290
Brand: Waters
€110.00
Product Image of Filter (Last Drop) with 10µm SS Filter
Filter (Last Drop) with 10µm SS Filter
Item number: WTPSL901291
Brand: Waters
€110.00
Product Image of Filter (Last Drop) with 2µm Pat Filter
Filter (Last Drop) with 2µm Pat Filter
Item number: WTPSL901292
Brand: Waters
€110.00
Product Image of Filter (Last Drop) with 5µm Pat Filter
Filter (Last Drop) with 5µm Pat Filter
Item number: WTPSL901294
Brand: Waters
€110.00
Product Image of Inline-Filterelement WAT 2695 Maintenance Kit
Inline-Filterelement WAT 2695 Maintenance Kit
Item number: AG8005-0424
Brand: Agilent Technologies
€47.00
Product Image of M715 Sealing for Waters 2995 Maintenance Kit
M715 Sealing for Waters 2995 Maintenance Kit
Item number: AG8005-0425
Brand: Agilent Technologies
€97.00
Product Image of Inline MicroFilter Kit, PEEK, 0.5µm, for 1/32'' OD
Inline MicroFilter Kit, PEEK, 0.5µm, for 1/32'' OD
Item number: UPM-525
Brand: Upchurch Scientific
€177.21
Product Image of Mini MicroFilter Assembly, 1µm, 5 capsules, 1pc/PAK
Mini MicroFilter Assembly, 1µm, 5 capsules, 1pc/PAK
Item number: UPM-533
Brand: Upchurch Scientific
€310.87
Product Image of Sure-Guard, disposable In-Line Filter, SS frit 0.5 um, Waters type, minimum order amount 4 pcs
Sure-Guard, disposable In-Line Filter, SS frit 0.5 um, Waters type, minimum order amount 4 pcs
Item number: JR-0641-SS05
Brand: Vici Jour
€40.75
Product Image of Sure-Guard, disposable In-Line Filter, SS frit 2 um, Waters type, minimum order amount 4 pcs
Sure-Guard, disposable In-Line Filter, SS frit 2 um, Waters type, minimum order amount 4 pcs
Item number: JR-0641-SS2
Brand: Vici Jour
€40.75
Product Image of Sure-Guard, disposable In-Line Filter, Ti frit 0.5 um, Waters type, minimum order amount 4 pcs
Sure-Guard, disposable In-Line Filter, Ti frit 0.5 um, Waters type, minimum order amount 4 pcs
Item number: JR-0641-TI05
Brand: Vici Jour
€40.75

Use of inline filters in chromatography

Impurities can not only get into the system from outside but also from the system itself. The main sources are mainly the piston seals the pump or the rotor seal the injection valve, which can produce abrasion with increasing operating time. This abrasion can lead to deposits / blockage on the stationary phase or in the HPLC system.

In addition to regular maintenance of the system it is recommended to use an inline filter to protect the column and the plant. But what is the inline filter and why makes its use a lot of sense? And what is important in choosing the right inline filter?

The in-line filter can be positioned at various locations of the HPLC system. If the inline filter is installed between the pump and the injector, particles and impurities are removed from the eluent. Likewise, abrasion of the piston seal is intercepted, so that the rotor seal of the injection valve is protected from abrasion and fine particles. When positioning directly in front of the column after the injection valve and contaminants from the sample are removed and abrasion of the rotor seals.

In addition to the inline filter it is usually recommended to use a guard column. Molecules that can be attached irreversibly to the main column can not be retained with the inline filter. Inline filters are available in various designs. In addition to housing, which is either made of PEEK or stainless steel can also choose between different fittings. These depend on the place where the inline filter should be installed. Thus, there are also housing, which are provided for the direct connection to the analytical column.

Accessories for the inline filters: frits

The frits for the inline filters are usually made of stainless steel and are often surrounded by a ring of PEEK. This serves as a seal ring, while minimizing the dead volume of the inline filter, so that no negative effects such as peak broadening can be expected. Stainless steel frits can be used for the current analysis. For applications requiring high corrosion resistance and biocompatibility, frits made of other materials such as Titanium or polymers are available. Also, the surrounding ring can be made of other materials, such as of PTFE. The user then has the possibility to choose a matching inline filter depending on the sample to be analyzed and the chemical properties of the mobile phase.

Typical pore sizes of the frits are 2 and 0.5 microns. When using columns with a particle size of <5 micron, frits with 0.5 microns should be used. For UHPLC systems and columns with particle sizes below 2 microns using frits with a pore size of 0.2 microns is recommended. The maximum pressure is 1000 bar and they have a low dead volume.

In the long term, the use of inline filters in the HPLC analysis has many advantages and saves money. Maintenance costs will be reduced and the facility and the separation column with usage of the inline filter will guarantee an extended service life.